Frequent
cases of residential fire have been a regular headache for fire departments
world over. Estimates suggest at least half of the lives that are lost due to
residential fires could be saved by installing early warning fire detection and
Alarm systems. They are very critical part of building management system
There
are 2 types of residential fire detection systems: smoke detectors and heat
detectors. The basic fire detection system in residential area depends upon
detectors which have a sensing chamber, alarm sounding device and a means of
electrical power transmission. There are 2 different kinds of smoke detectors:
photoelectric and ionisation. Photoelectric one is responsive to fires that
begin with a long period of smouldering, whereas ionisation one is more
responsive to flame fires. Since prediction of fire is unpredictable, for
maximum protection both technologies are in use.
Photoelectric smoke
detectors:
Smoke
can block or obscure the beam. When smoke blocks the light beam from the light
source, reduction in light reaching the photosensitive device alters its
output. Change in this output is sensed by the detector circuitry and alarm is
initiated. Photoelectric smoke detectors are better suited to detect slow
smouldering fires.
Ionisation smoke
detectors: Ionisation
smoke detectors have a small amount of radioactive material. When smoke enters
the chamber, it disrupts the flow of ions, thus reducing the flow of current
and activating the alarm. They are more suitable for detection of fast flaming
fires.
Smoke
detectors offer earliest possible fire detection and alarm system/warning of
fire. In certain circumstances where standard fire detectors are unsuitable,
special purpose detectors are used. Laser based fire detectors are used where
extremely early fire warning is desired. They are ultra sensitive to smoke
being 100 times more sensitive to standard ones.
Lately
designers of fire detection & alarm systems have begun to introduce fire
detectors that combine photoelectric and ionisation sensor in the same unit.
The units combine the advantage of both the sensors into an advanced unit that
detects smoke from a broader spectrum of fire. A residential fire detection and
alarm system may also include a heat detector. Heat detectors wake up when air
temperature exceeds the preset range or rate of rise is beyond preset limit,
then they raise an laert when temperature in the vicinity rises.
For More, Visit at http://www.sofcontraining.com/builiding-management.htm
or
Call Now Our TOLL FREE No. 1800 - 200 – 4051
Noida +91-9873630785
Delhi +91-9711861537
Gurgaon +91-9873588305
Lucknow +91-9838834288
Allahabad +91-7704003025
Jaipur +91-8058033551
Mohali +91-9873349806
Bhopal +91-9755559168
Vadodara +91-9898666980
Ahmedabad +91-9227185900
Pune +91-7387700416
or
Call Now Our TOLL FREE No. 1800 - 200 – 4051
Noida +91-9873630785
Delhi +91-9711861537
Gurgaon +91-9873588305
Lucknow +91-9838834288
Allahabad +91-7704003025
Jaipur +91-8058033551
Mohali +91-9873349806
Bhopal +91-9755559168
Vadodara +91-9898666980
Ahmedabad +91-9227185900
Pune +91-7387700416
Thanks for sharing blog and give to information regarding GPS Tracker ProviderFire Alarm/ Smoke Detector in Ahmedabad Fire detection & Fire Alarm systems
ReplyDelete